M5S700T4LC-MCCB UL 489, M5S, 800 A Frame Size, 42kA@480Vac, 700A, 4P, Lug Line/Load Side
Free Shipping on orders over $50
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 8 - Jul 13
Description
M5S700T4LC-MCCB UL 489, M5S, 800 A Frame Size, 42kA@480Vac, 700A, 4P, Lug Line/Load SidePrimary brand NOARK Main function Moulded Case Circuit Breaker (MCCB) Product series family name Electrical protection > Circuit breakers > AC Moulded Case Circuit Breakers (MCCBs) Sub range name Ex9M5 series Functions Moulded Case Circuit Breaker (MCCB) Poles 4 poles (4P4d) Trip current rating 700 Frame current rating 800 Rated operating voltage (Ue) (IEC) 690 Rated voltage (AC) 600Vac Rated impulse voltage (Uimp) 8 Rated insulation voltage (Ui) 800
higher breaker derating) Dimensions H430mm x W549
Air Circuit Breakers Product title Withdrawable / drawout Air Circuit Breaker (ACB) - NOARK A32 series Description generating formula A Description Withdrawable / drawout Air Circuit Breaker (ACB) - UL1066 - NOARK (A32 series) - 3-poles (3P3d) - Rated current 800A - Interrupting capacity 100kA (254-635Vac) - Withdrawable / drawout chassis with rear vertical connection pads - equivalent to 1800080 Catalogue connector NOARK - A32 series
test procedure) Electrical durability 6000 hours Mechanical durability 10000 hours Short Description Power switch-disconnector MCS - 1800146 - UL1066 - 3200A frame - 3P3d - 2000A rated - 600Vac Type Option = special connection pads (horizontal) Rated current 2000A Short circuit withstand current(Icw) 85kA (240Vac)
Electrical circuits protection Product title Undervoltage (U/V) trip release coil - NOARK Description generating formula A Description Undervoltage (U/V) trip release coil - for M1 frame size - NOARK - 220Vac-240Vac control voltage - equivalent to 1100530 Catalogue connector NOARK - Circuit breaker accessories
Moulded Case Circuit Breakers (MCCB) Product title Moulded Case Circuit Breaker (MCCB) - NOARK Ex9M1 series Description generating formula A Description Moulded Case Circuit Breaker (MCCB) - UL489 listed - NOARK (Ex9M1 series) - 3-poles (3P3d) - Rated current 30A - Interrupting capacity 14kA (600Vac) - Lugs on both load and line sides - Thermal-Magnetic (fixed) (FT/FM (Fixed Thermal / Fixed Magnetic)) trip unit - equivalent to 1100030 Catalogue connector NOARK - Ex9M1 series
M1N100T1L Benefits Ex9M series offers
1101988 Manufacturer product status Commercialized Equivalent to 1101988 Compliant with standard(s) UL489 listed
Switch-disconnectors Product title Front-operated toggle moulded case switch-disconnector (MCS) - NOARK Ex9M1D series Description generating formula A Description Front-operated toggle moulded case switch-disconnector (MCS) - non-fusible - UL489 listed - NOARK (Ex9M1D series) - 2-poles (2P2d) - Rated current 100A - Interrupting capacity 20kA (600Vac) - Lugs on both load and line sides - equivalent to 1100458 Catalogue connector NOARK - Ex9M1D series
higher breaker derating) Short circuit breaking rating 85kA (254-635Vac) Dimensions H430mm x W435
1102594 Manufacturer product status Commercialized Equivalent to 1102594 Technical compatibility with for M3 frame size Short Description Individual mechanical lug - 1102594 - for M3 Type Option = Standard (No options) Net weight 250 Contents 1pc Category code Global_Cat_001001
1800412 Manufacturer product status Commercialized Equivalent to 1800412 Electrical durability 12500 hours Mechanical durability 2000 hours Short Description Fixed-type DC MCS - 1800412 - D-type wiring - 2500A frame - 4P4d - 1000A rated - rear fixed vertical connection - 1500Vdc Type Option = special connection pads (vertical) Rated current 1000A Short circuit withstand current(Icw) 125kA (1500Vdc) Rated Voltage (DC) 1500Vdc Response time (breaking time) max
04" Order code / Manufacturer SKU MD11NC
Easy Shipping
Quick Dispatch:
Your M5S700T4LC-MCCB UL 489, M5S, 800 A Frame Size, 42kA@480Vac, 700A, 4P, Lug Line/Load Side orders ship within 1-2 business days.
Delivery Options:
- Standard: 3-7 business days
- Fast: 2-3 business days
- Express: 1-2 business days
Order Tracking:
You'll receive a tracking link by email once your M5S700T4LC-MCCB UL 489, M5S, 800 A Frame Size, 42kA@480Vac, 700A, 4P, Lug Line/Load Side ships.
Need Help?
Questions about M5S700T4LC-MCCB UL 489, M5S, 800 A Frame Size, 42kA@480Vac, 700A, 4P, Lug Line/Load Side, sizing, or delivery? We're just an email away.
Live Shipping Estimates:
Enter your location at checkout to see available shipping methods and costs for M5S700T4LC-MCCB UL 489, M5S, 800 A Frame Size, 42kA@480Vac, 700A, 4P, Lug Line/Load Side in your area.
Get Shipping Estimates
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
You may also like
M5H600T3L-MCCB UL 489, M5H, 800 A Frame Size, 100kA@480Vac, 600A, 3P, Lug Line/Load Side
2479.50
★★★★☆4.8 (126)
Designer Surface Mount Lighted Push Button in Burnished Brass
29.00
★★★★★4.9 (98)
Slope Mount Adapter in Brushed Polished Nickel
112.50
★★★★★5.0 (157)
UVT24NH-MCCB/MCP/MCS Under-Voltage Trip UL 489 , M4/M5, 220-250Vdc
73.77
★★★★★4.7 (84)
M5S800T2L-MCCB UL 489 - 3P, M5S, 800 A Frame Size, 42kA@480Vac, 800A, 2P, Lug Line/Load Side
1726.50
★★★★★4.9 (203)
M5N700T4LC-MCCB UL 489, M5N, 800 A Frame Size, 65kA@480Vac, 700A, 4P, Lug Line/Load Side
2802.00
★★★★★5.0 (176)
M6D12004LF-MCS UL 489 , M6D, 1200 A Frame Size, 42kA@480Vac, 1200A, 4P, Lug Line/Load Side
2926.50
★★★★★4.8 (132)